Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.131
Filtrar
1.
Clin Oral Investig ; 28(4): 224, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38509406

RESUMEN

OBJECTIVES: To evaluate the bleaching efficacy and permeability of hydrogen peroxide (HP) in the pulp chamber of human teeth bleached with lower concentrations of carbamide peroxide gel (4%, 5% and 7% CP). MATERIALS AND METHODS: Bleaching gels with lower concentrations were formulated and a commercial standard gel, 10% CP, was used as a reference. Fifty-six human premolars were randomly divided into four groups. Applications of the bleaching gel were made for 3 h for 21 days. The bleaching efficacy was evaluated by digital spectrophotometry on 1, 7, 14 and 21 days, with analysis in the ∆Eab, ∆E00 and WID color spaces. The concentration of HP in the pulp chamber was measured in the same periods by UV-Vis spectrophotometry (µg/mL). Two-way repeated analysis of variance (ANOVA) examined bleaching efficacy and HP permeability, followed by Tukey's post-hoc test (α = 0.05). RESULTS: All groups showed significant color changes, with no statistical differences after the second and third week of bleaching (p > 0.05). The 'time' factor was statistically different (p < 0.05), increasing the bleaching efficacy throughout the treatment. The 4% CP group had lower HP levels in the pulp chamber (p < 0.05). CONCLUSIONS: The results seem promising, revealing that low concentration gels are as effective as 10% CP with the benefit of reducing the amount of HP in the pulp chamber. CLINICAL RELEVANCE: Low concentration 4% PC and 5% PC maintains bleaching efficacy, reduces the penetration of HP peroxide into the pulp chamber, and may reduce tooth sensitivity.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Peróxido de Carbamida , Cavidad Pulpar , Blanqueadores Dentales/farmacología , Peróxido de Hidrógeno , Blanqueamiento de Dientes/métodos , Ácido Hipocloroso , Geles , Urea/farmacología , Peróxidos/farmacología
2.
J Mech Behav Biomed Mater ; 153: 106497, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38458078

RESUMEN

OBJECTIVE: To evaluate whether coating enamel with a polymeric primer (PPol) containing titanium tetrafluoride (TiF4) before applying a bleaching gel with 35% H2O2 (35% BG) increases esthetic efficacy, prevents changes in morphology and hardness of enamel, as well as reduces the cytotoxicity from conventional in-office bleaching. MATERIALS AND METHODS: Standardized enamel/dentin discs were stained and bleached for 45 min (one session) with 35% BG. Groups 2TiF4, 6TiF4, and 10TiF4 received the gel on the enamel previously coated with PPol containing 2 mg/mL, 6 mg/mL, or 10 mg/mL, respectively. No treatment or application of 35% BG directly on enamel were used as negative control (NC), and positive control (PC), respectively. UV-reflectance spectrophotometry (CIE L*a*b* system, ΔE00, and ΔWI, n = 8) determined the bleaching efficacy of treatments. Enamel microhardness (Knoop, n = 8), morphology, and composition (SEM/EDS, n = 4) were also evaluated. Enamel/dentin discs adapted to artificial pulp chambers (n = 8) were used for trans-amelodentinal cytotoxicity tests. Following the treatments, the extracts (culture medium + bleaching gel components diffused through the discs) were collected and applied to odontoblast-like MDPC-23 cells, which were assessed concerning their viability (alamarBlue, n = 8; Live/Dead, n = 4), oxidative stress (n = 8), and morphology (SEM). The amount of H2O2 in the extracts was also determined (leuco crystal violet/peroxidase, n = 8). The numerical data underwent one-criterion variance analysis (one-way ANOVA), followed by Tukey's test, at a 5% significance level. RESULTS: Regarding the ΔE00, no difference was observed among groups 2TiF4, 6TiF4, and PC (p > 0.05). The ΔWI was similar between groups 2TiF4 and PC (p > 0.05). The ΔWI of group 6TiF4 was superior to PC (p < 0.05), and group 10TiF4 achieved the highest ΔE00 and ΔWI values (p < 0.05). Besides limiting enamel microstructural changes compared to PC, group 10TiF4 significantly increased the hardness of this mineralized dental tissue. The highest cellular viability occurred in 10TiF4 compared to the other bleached groups (p < 0.05). Trans-amelodentinal H2O2 diffusion decreased in groups 2TiF4, 6TiF4, and 10TiF4 in comparison with PC (p < 0.05). CONCLUSION: Coating enamel with a PPol containing TiF4 before applying a 35% BG may increase enamel microhardness and esthetic efficacy and reduce the trans-amelodentinal cytotoxicity of conventional in-office tooth bleaching. The PPol containing 10 mg/mL of TiF4 promoted the best outcomes.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Peróxido de Hidrógeno/química , Blanqueadores Dentales/farmacología , Dentina , Blanqueamiento de Dientes/efectos adversos , Esmalte Dental
3.
J Dent ; 143: 104902, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38432352

RESUMEN

OBJECTIVE: To investigate the effect of tooth whitening on biomechanical properties of vacuum-formed retainers (VFRs). METHODS: Using a split-mouth, randomised controlled trial design, thirty participants were randomly allocated to receive whitening on either the upper or the lower arch, using 10 % carbamide peroxide for two weeks. Biomechanical properties such as hardness, tensile strength, and surface roughness were assessed two weeks after whitening was completed. RESULTS: Tensile strength of the whitening arch (mean ± SD: 40.93 ± 3.96 MPa) was significantly lower than that of the control (47.40 ± 5.03 MPa) (difference 6.47 MPa, 95 % CI 4.51 - 8.42, p < 0.001). Hardness and internal roughness of the whitening arch (VHN = 14.63 ± 2.29 N/mm2 and Ra = 1.33 ± 0.35 µm, respectively) were significantly greater than those of the control (12.22 ± 1.86 N/mm2 and 0.96 ± 0.29 µm, respectively) (differences 2.41 N/mm2, 95 % CI 1.56 - 3.25, p < 0.001 and 0.37 µm, 95 % CI 0.23 - 0.51, p < 0.001, respectively). The whitening arch showed greater tooth colour change (ΔE = 6.00 ± 3.32) than the control (ΔE = 2.50 ± 1.70) (difference = 3.50, 95 % CI 2.43 - 4.56, p < 0.001). CONCLUSIONS: Based on this short-term study, marked tooth colour change was achieved by whitening with VFRs as the whitening trays, but this changed the VFRs' biomechanical properties, including a decrease in tensile strength and an increase in hardness and internal roughness. CLINICAL SIGNIFICANCE: The application of carbamide peroxide in VFRs may compromise their mechanical properties.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Diente , Humanos , Peróxido de Carbamida , Vacio , Blanqueadores Dentales/farmacología , Urea , Peróxidos/farmacología , Peróxido de Hidrógeno/farmacología , Combinación de Medicamentos
4.
J Dent ; 144: 104951, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38508441

RESUMEN

OBJECTIVES: This study evaluated the efficacy of simulated brushing with toothpastes containing different concentrations of hydrogen peroxide (HP) in pulp chamber penetration and color change. Also, physical-chemical properties (concentration, pH and viscosity) were evaluated. METHODS: Forty-nine premolars were divided into seven groups (n = 7): untreated (control); whitening gel (White Class 6 %, 6 %BG) with one 90  min application (6 %BG 90  min) and 14 applications of 90  min (6 %BG 14×90 min); toothpastes (Colgate Luminous White Glow 3 %, 3 %TP; Crest 3D White Brilliance 4 %, 4 %TP; Colgate Optic White Pro-Series 5 %, 5 %TP) and 6 %BG toothbrushing for 14 applications of 90 s. HP penetration into the pulp chamber was measured through UV-Vis spectrophotometry and color change with a spectrophotometer (ΔEab, ΔE00, and ΔWID). Initial concentration, pH, and viscosity were measured through Titration, Digital pH-meter, and Rheometer, respectively. Statistical analysis used one-way ANOVA and Tukey's test (α = 0.05). RESULTS: 6 %BG (14×90 min) and 4 %TP groups showed acidic pH and higher concentrations of HP in the pulp chamber compared to the other groups (p < 0.05). On the other side, 3 %TP and 5 %TP groups showed alkaline pH, higher viscosity between the toothpastes and lower HP penetration (p < 0.05). The 6 %BG AH (14×90 min) group exhibited the most significant color change (ΔEab, ΔE00, and ΔWID) (p < 0.05). CONCLUSIONS: Brushing with whitening toothpaste with an acidic pH leads to greater HP penetration into pulp chamber; but, even when a high concentrated HP whitening toothpaste was used, a lower whitening effect was observed when compared to a two-week at-home bleaching. CLINICAL SIGNIFICANCE: Whitening toothpastes containing up to 5 % HP produced lower whitening effect than two-week at-home bleaching. Additionally, HP was detected within the pulp chamber which can potentially impact in tooth sensitivity.


Asunto(s)
Color , Cavidad Pulpar , Peróxido de Hidrógeno , Blanqueadores Dentales , Blanqueamiento de Dientes , Cepillado Dental , Pastas de Dientes , Peróxido de Hidrógeno/química , Humanos , Blanqueadores Dentales/farmacocinética , Blanqueadores Dentales/química , Concentración de Iones de Hidrógeno , Pastas de Dientes/química , Blanqueamiento de Dientes/métodos , Cavidad Pulpar/metabolismo , Viscosidad , Ensayo de Materiales , Factores de Tiempo , Espectrofotometría , Diente Premolar , Espectrofotometría Ultravioleta
5.
J Appl Oral Sci ; 32: e20230416, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38536995

RESUMEN

BACKGROUND: At low concentrations used for in-office bleaching gels, such as 6% HP, gingival barrier continues to be performed. If we take into account that, in the at-home bleaching technique, no barrier is indicated, it seems that the use of a gingival barrier fails to make much sense when bleaching gel in low concentration is used for in-office bleaching. OBJECTIVE: This double-blind, split-mouth, randomized clinical trial evaluated the gingival irritation (GI) of in-office bleaching using 6% hydrogen peroxide (HP) with and without a gingival barrier in adolescents, as well as color change and the impact of oral condition on quality of life. METHODOLOGY: Overall, 60 participants were randomized into which side would or would not receive the gingival barrier. In-office bleaching was performed for 50 minutes with 6% HP in three sessions. The absolute risk and intensity of GI were assessed with a visual analogue scale. Color change was assessed using a digital spectrophotometer and color guides. The impact of oral condition on quality of life was assessed using the Brazilian version of the Oral Health Impact Profile (α=0.05). RESULTS: The proportion of patients who presented GI for the "with barrier" group was 31.6% and for the "without barrier" group, 30% (p=1.0). There is an equivalence for the evaluated groups regarding GI intensity (p<0.01). Color change was detected with no statistical differences (p>0.29). There was a significant impact of oral condition on quality of life after bleaching (p<0.001). CONCLUSIONS: The use or not of the gingival barrier for in-office bleaching with 6% HP was equivalent for GI, as well as for bleaching efficacy, with improvement in the impact of oral condition on quality of life.


Asunto(s)
Sensibilidad de la Dentina , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Adolescente , Peróxido de Hidrógeno , Blanqueamiento de Dientes/efectos adversos , Blanqueamiento de Dientes/métodos , Blanqueadores Dentales/efectos adversos , Calidad de Vida , Resultado del Tratamiento , Sensibilidad de la Dentina/inducido químicamente , Geles
6.
Clin Oral Investig ; 28(3): 189, 2024 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-38430338

RESUMEN

OBJECTIVES: To assess color change efficacy and the adverse effects of varied over-the-counter (OTC) bleaching protocols. METHODOLOGY: The study included randomized clinical trials evaluating color changes from OTC bleaching agents. Nine databases were searched, including the partial capture of the grey literature. The RoB2 tool analyzed the individual risk of bias in the studies. Frequentist network meta-analyses compared treatments through common comparators (∆Eab* and ∆SGU color changes, and tooth sensitivity), integrating direct and indirect estimates and using the mean and risk differences as effect measures with respective 95% confidence intervals. The GRADE approach assessed the certainty of the evidence. RESULTS: Overall, 37 remaining studies constituted the qualitative analysis, and ten composed the meta-analyses. The total sample included 1,932 individuals. ∆Eab* was significantly higher in groups 6% hydrogen peroxide (HP) strips (≥ 14 h). ∆SGU was significantly higher in groups at-home 10% carbamide peroxide (CP) (≥ 14 h), followed by 6% HP strips (≥ 14 h) and 3% HP strips (≥ 14 h). At-home 10% CP (7-13 h) and placebo showed lower risks of tooth sensitivity without significant differences between these treatments. CONCLUSION: Considering the low level of evidence, OTC products presented satisfactory short-term effects on tooth bleaching compared to the placebo, with little to no impact on dentin hypersensitivity and gingival irritation. CLINICAL RELEVANCE: OTC products are proving to be practical alternatives for tooth whitening. However, patients should be advised about the possible risks of carrying out such procedures without professional supervision.


Asunto(s)
Sensibilidad de la Dentina , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Peróxido de Carbamida , Color , Sensibilidad de la Dentina/tratamiento farmacológico , Peróxido de Hidrógeno , Ácido Hipocloroso , Metaanálisis en Red , Medicamentos sin Prescripción/efectos adversos , Peróxidos , Blanqueamiento de Dientes/efectos adversos , Blanqueamiento de Dientes/métodos , Blanqueadores Dentales/efectos adversos , Blanqueadores Dentales/farmacología , Urea
7.
Arch Oral Biol ; 161: 105937, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38442471

RESUMEN

OBJECTIVE: To evaluate the role of induced nitric oxide synthase (iNOS) in nociception/orofacial discomfort in rats submitted to tooth whitening with hydrogen peroxide (H2O2). DESIGN: Wistar rats were divided into three groups (n = 24/group): a sham group not submitted to whitening treatment, a saline group submitted to whitening treatment, and a test group submitted to whitening treatment and blockade of iNOS with aminoguanidine 50 mg/kg/day. After 24 and 48 h, and 7 days, the animals were euthanized to collect trigeminal ganglia and maxillae to histomorphometric analysis (size of neuronal bodies and percentage of pulp area filled by vessels) and behavior/nociception (Grimace scales, scratching and biting counting, weight loss and nociception assay). ANOVA-1- or - 2-way tests were used (p < 0.05, GraphPadPrism 5.0). RESULTS: The aminoguanidine-treated group showed a reduction in nociceptive threshold in the masseteric region (p < 0.001), Grimace scale scores (p < 0.001), number of scratching (p = 0.011) and body mass loss (p = 0.007). After 24 and 48 h of tooth bleaching, the saline group showed a significant increase in the mean area of the blood vessels (p = 0.020) and iNOS immunostaining in odontoblasts (p = 0.002) and non-odontoblasts cells (p = 0.025). Aminoguanidine reversed both increases. Tooth bleaching reduced the mean area of neuronal bodies, and aminoguanidine significantly reversed it (p = 0.019), but an increase in GFAP immunostaining in neuronal bodies did not reduce after seven-days or after aminoguanidine treatment (p = 0.003). CONCLUSION: iNOS blockage by aminoguanidine plays an important role in nociception and orofacial discomfort by control of inflammation in dental pulp after tooth bleaching with hydrogen peroxide (H2O2) 35%.


Asunto(s)
Guanidinas , Blanqueadores Dentales , Blanqueamiento de Dientes , Ratas , Animales , Peróxido de Hidrógeno/farmacología , Nocicepción , Óxido Nítrico , Ratas Wistar , Óxido Nítrico Sintasa
8.
Oper Dent ; 49(2): 157-165, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38349817

RESUMEN

OBJECTIVES: To evaluate the volume and depth of enamel loss promoted by 37.5% and 7.5% hydrogen peroxide (HP) gels, and quantify the loss of calcium (Ca) and phosphate (P) ions by using ion chromatography (IC) analysis after bleaching. METHODS: Sixty bovine enamel specimens were randomly divided into three groups: Control - no bleaching gel; HP37.5%, application of HP 37.5% for 45 minutes for 14 days; and HP7.5%, application of HP 7.5% for 3 applications of 8 minutes. The surface analysis (n=5) was performed using a scanning electron microscope (SEM) and dispersive energy system (EDS) to calcium and phosphorus dosage. The micro-CT was used for the enamel loss analysis (n=5). IC was used to analyze extracted Ca and P (n=10). Data were analyzed by one-way ANOVA and two-way repeated measures ANOVA, followed by Tukey and Dunnett's tests (α=0.05). RESULTS: Significantly higher volume and depth of enamel loss were found for bleached groups compared with the control group. HP7.5% had significantly higher enamel change than HP37.5%. SEM showed higher enamel porosity for HP37.5% and HP7.5% compared to control. The IC demonstrated a significant increase of Ca incorporated into the gel, however, only HP7.5% had a higher P presence than the control group. The HP7.5% showed higher Ca and P ion exchange than HP37.5% (p<0.001). CONCLUSION: HP37.5% and HP7.5%, caused enamel mineral changes compared with the control group. The IC method was demonstrated to be an effective methodology for detecting enamel mineral loss by the bleaching gel.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Animales , Bovinos , Calcio , Blanqueamiento de Dientes/métodos , Esmalte Dental , Microtomografía por Rayos X , Peróxido de Hidrógeno/química , Minerales , Fosfatos , Geles
9.
J Esthet Restor Dent ; 36(3): 437-444, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38303586

RESUMEN

OBJECTIVE: This study aimed to investigate the relationship between patient satisfaction of outcomes and tooth color changes during and after tooth bleaching. METHODS: In this clinical trial, 63 volunteers participated in an in-office bleaching procedure using a 40% hydrogen peroxide gel. The treatment consisted of two sessions, each comprising two 30-min applications of the bleaching gel. The L*, a*, and b* values of six maxillary anterior teeth were measured at baseline (T1), after the first bleaching session (T2), after the second bleaching session (T3), 1 week after the second in-office bleaching session (T4), and 3 weeks after the second in-office bleaching session (T5). The color differences (ΔE00 ) were calculated using CIEDE2000. A satisfaction scale with a score ranging from 0 to 3 was used to record participants' level of satisfaction with their tooth color at each time point. The data were statistically analyzed using repeated measures analysis of variance and logistic regression (α = 0.05). RESULTS: Significant correlations were observed between ΔL*, Δb*, and ΔE00 values at T3 and patient satisfaction (all p < 0.05). The regression model indicated a more pronounced impact of Δb* on patient satisfaction compared to ΔL*. The established regression models were as follows: Logit (PL*b* ) = -4.354 + 0.271ΔL* - 0.585Δb* and Logit (PΔE00 ) = -2.552 + 0.521ΔE00 . The findings suggested a minimum ΔE00 value of 4.90 for satisfactory results. A minimum ΔE00 value of 3.9, 5.0, and 6.8 was necessary for central incisors, lateral incisors, and canines, respectively, to achieve a satisfactory result. CONCLUSIONS: The ΔL*, Δb*, and ΔE00 values were found to be significantly correlated with patient satisfaction after bleaching. Δb* was identified as having a greater influence on patient satisfaction than ΔL* values in the regression model. Furthermore, attaining a minimum ΔE00 value of 4.90 is necessary to achieve satisfactory outcomes. A greater ΔE00 value is needed for canines than for incisors to achieve equivalent patient satisfaction. CLINICAL SIGNIFICANCE: This study emphasizes the importance of considering the extent of color change needed to achieve patient satisfaction after tooth bleaching procedures.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Diente , Humanos , Color , Peróxido de Hidrógeno , Incisivo , Satisfacción del Paciente , Blanqueamiento de Dientes/métodos
10.
Clin Oral Investig ; 28(3): 171, 2024 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-38400920

RESUMEN

OBJECTIVES: This study aims to assess hydrogen peroxide (HP) penetration within the pulp chamber, color change (CC), physical-chemical properties, and temperature using in-office different concentration bleaching gels with or without violet light. MATERIALS AND METHODS: Fifty teeth were divided into five groups (n = 10) based on the HP concentration bleaching gels used (6% and 35%) and the used violet light (with or without). HP penetration within the pulp chamber was measured using UV-Vis. The CC was evaluated with a digital spectrophotometer. Initial and final concentration, and pH were measured through titration, and a Digital pHmeter, respectively. Temperature analyses were measured through a thermocouple. Statistical analysis included two-way ANOVA, Tukey's, and Dunnett's test (α = 0.05). RESULTS: The presence of violet light did not affect the amount of HP within the pulp chamber, or the CC (p > 0.05). Greater penetration of HP was observed within the pulp chamber, as well as CC when using 35% HP (p < 0.05). The final concentration of both gels was lower than the initial concentration, regardless of the use of violet light (p < 0.05). The initial and final pH levels remained neutral and stable (p > 0.05). The pulp temperature increased when the gels were used in conjunction with violet light (p < 0.05). CONCLUSIONS: Using violet light in conjunction with 6% or 35% HP does not alter the physical properties of the bleaching agents, the penetration of HP or enhance color change. However, an increase in temperature was observed when violet light was applied associated with bleaching gels. CLINICAL RELEVANCE: While the simultaneous use of violet light with hydrogen peroxide 6% or 35% does not alter the material's properties, it also does not bring benefits in reducing hydrogen peroxide penetration and improving color change. Furthermore, the use of violet light increases pulp temperature.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Peróxido de Hidrógeno , Peróxidos , Ácido Hipocloroso , Geles
11.
J Appl Oral Sci ; 32: e20230336, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38324805

RESUMEN

OBJECTIVES: This study aimed to analyze the cost-effectiveness of whitening toothpastes and at-home bleaching for the treatment of tooth discoloration. METHODOLOGY: A cost-effectiveness economic analysis was conducted, and eight randomized clinical trials were selected based on the whitening agent product used: blue covarine dentifrices (BCD), hydrogen peroxide dentifrices (HPD), dentifrices without bleaching agents (CD, negative control), and 10% carbamide peroxide (CP10, positive control) for at-home bleaching. The consumer/patient perspective was adopted, macro-costing techniques were used and a decision tree model was performed considering the costs in the American and Brazilian markets. The color change evaluation (ΔE*ab) was used to calculate the effectiveness of tooth bleaching. A probabilistic analysis was performed using a Monte Carlo simulation and incremental cost-effectiveness ratios were obtained. RESULTS: CP10 resulted in the highest cost-effectiveness compared to the use of dentifrices in both markets. In Brazil, HPD was more cost-effective than BCD and CD. In the US, the increased costs of HPD and BCD did not generate any whitening benefit compared to CD. CONCLUSIONS: CP10 was more cost-effective than BCD and HPD for tooth bleaching from the perspectives of the Brazilian and American markets. Decision-making should consider the use of CP10 for treating tooth discoloration.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Decoloración de Dientes , Humanos , Color , Análisis Costo Beneficio , Dentífricos/uso terapéutico , Peróxido de Hidrógeno/uso terapéutico , Blanqueamiento de Dientes/métodos , Blanqueadores Dentales/uso terapéutico , Decoloración de Dientes/tratamiento farmacológico , Pastas de Dientes/uso terapéutico , Urea , Ensayos Clínicos Controlados Aleatorios como Asunto
12.
J Dent ; 142: 104875, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38309571

RESUMEN

OBJECTIVE: The application of anti-inflammatories as topical desensitizers before dental bleaching is an approach to reduce bleaching-induced tooth sensitivity (TS). This randomized controlled trial compared the risk and intensity of TS and the color change resulting from in-office dental bleaching after using an experimental desensitizing gel containing ibuprofen and arginine. METHODS: Sixty-two participants with upper canine shades A2 or darker were randomly assigned to either the ibuprofen-arginine desensitizing group or the placebo group. The desensitizing gel was applied for 15 min before in-office bleaching with 35 % hydrogen peroxide gel for 50 min (2 sessions). To assess the absolute risk and intensity of TS, visual (0-10) and numeric rating (0-5) scales were used, and group comparisons were made using the McNemar test, Wilcoxon test, and paired Student t-test (α = 0.05). Color change was evaluated using Vita Classical, Vita Bleachedguide (ΔSGU), and Vita EasyShade (ΔEab, ΔE00, and ΔWID) before and one month after the bleaching procedure. Group comparisons for color change were done using a paired t-test (α = 0.05). RESULTS: The odds ratio for TS was 0.14 [95 % CI 0.02 to 0.6], meaning lower odds of TS for the desensitizing gel. A lower intensity of TS was also observed for the experimental group (p < 0.005) up to 48 h after bleaching. All color evaluation tools demonstrated effective and similar whitening for both groups (p > 0.05). CONCLUSIONS: Using the experimental desensitizing gel containing ibuprofen and arginine effectively reduced the risk and intensity of TS without compromising the bleaching efficacy. CLINICAL RELEVANCE: The topical application of ibuprofen/arginine on the in-office bleaching reduced risk and intensity of bleaching-induced tooth sensitivity.


Asunto(s)
Sensibilidad de la Dentina , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Sensibilidad de la Dentina/inducido químicamente , Sensibilidad de la Dentina/prevención & control , Blanqueadores Dentales/efectos adversos , Ibuprofeno/uso terapéutico , Blanqueamiento de Dientes/efectos adversos , Blanqueamiento de Dientes/métodos , Peróxido de Hidrógeno/efectos adversos , Compuestos de Sodio , Arginina/uso terapéutico , Resultado del Tratamiento
13.
Stomatologiia (Mosk) ; 103(1): 16-22, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38372602

RESUMEN

THE AIM OF THE STUDY: Optimization of methods for treating dental discoloration using whitening systems based on hydrogen peroxide by laboratory studying their chemical properties. MATERIAL AND METHODS: The effectiveness of the bleaching system was assessed by quantitatively assessing the color change of model samples of hydroxyapatite (HAP) in the CIE L*a*b* system on a Spectron-M color analyzer after exposure to coloring food media. Safety assessment was carried out on samples made from teeth removed according to indications. RESULTS: The results of laboratory tests allow us to conclude that the Chairside Light Whitening System professional teeth whitening system fläsh. (WHITEsmile GmbH, Germany) has high whitening efficiency with a whitening degree of ~84%, which significantly exceeds the norm of GOST R 702.3.004-2021. the microhardness of the enamel of samples exposed to the whitening gel for 15 minutes changes extremely little. After exposure of the studied samples to the Chairside Light Whitening System fläsh whitening system for 45 minutes, an increase in digital microhardness indicators is observed, which indicates the dynamics of processes demineralizing the hard tooth structure. CONCLUSIONS: Chairside Light Whitening System fläsh professional teeth whitening system has high whitening efficiency with minimal impact on the teeth structure and high safety.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Diente , Humanos , Blanqueamiento de Dientes/efectos adversos , Peróxido de Hidrógeno , Esmalte Dental
14.
J Am Dent Assoc ; 155(4): 304-311, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38244017

RESUMEN

BACKGROUND: The authors evaluated the synergistic analgesic effect of preemptive administration of 400 mg of ibuprofen (IBU) and potassium fluoride 2% (KF2), both in isolation or combination, on the painful perception of tooth sensitivity after tooth bleaching. METHODS: Fifteen patients participated in this triple-blind, randomized, placebo-controlled clinical trial. The study used a crossover design for drug administration and a split-mouth design for desensitizer agent. Four paired groups were formed: IBU plus KF2 (IBU + KF2); IBU (IBU + placebo KF); KF2 (placebo IBU + KF2), and placebo (placebo IBU + placebo KF). The outcome measure was the perception of tooth sensitivity, assessed using a visual analog scale. Data were collected at 4 different times: immediately after tooth bleaching (baseline) and after 6, 30, and 54 hours. Statistical analysis was performed using the Friedman test and relative risk. RESULTS: IBU plus KF2 was found to be more effective in reducing tooth sensitivity immediately after bleaching (baseline) compared with the placebo group (P < .05). The risk of experiencing moderate or severe tooth sensitivity was approximately 4 times higher in the placebo group than in the IBU plus KF2 group (relative risk, 4.00; 95% CI, 1.01 to 15.81; P = .025). CONCLUSIONS: The combined use of 400 mg of IBU and KF2 appears to be beneficial in managing postbleaching tooth sensitivity. It provides a superior analgesic effect compared with placebo. PRACTICAL IMPLICATIONS: The preemptive administration of IBU plus KF2 reduces tooth sensitivity after tooth whitening when compared with placebo. This clinical trial was registered in the Brazilian Clinical Trials Registry Platform. The registration number is U1111-1249-8191.


Asunto(s)
Sensibilidad de la Dentina , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Ibuprofeno/efectos adversos , Sensibilidad de la Dentina/etiología , Sensibilidad de la Dentina/prevención & control , Sensibilidad de la Dentina/tratamiento farmacológico , Peróxido de Hidrógeno , Blanqueamiento de Dientes/efectos adversos , Analgésicos , Método Doble Ciego , Resultado del Tratamiento
15.
BMC Oral Health ; 24(1): 139, 2024 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-38281911

RESUMEN

BACKGROUND: Light-cured resins are widely used as gingival barriers to protect the gums from highly concentrated peroxides used in tooth bleaching. The impact of barrier brand on clinical outcomes is typically considered negligible. However, there is limited evidence on the effects of different brands on operator experience, barrier adaptation, and patient comfort. OBJECTIVE: This clinical trial assessed the impact of four commercial gingival barrier brands (Opaldam, Topdam, Lysadam, and Maxdam) on operator perception, adaptation quality, and patient comfort. METHODS: Twenty-one undergraduate students placed gingival barriers in a randomized sequence using blinded syringes. Photographs of the barriers were taken from frontal and incisal perspectives. After bleaching procedures, operators rated handling features and safety using Likert scale forms. Two experienced evaluators independently assessed barrier adaptation quality on a scale from 1 (perfect) to 5 (unacceptable). The absolute risk of barrier-induced discomfort was recorded. Data were analyzed using Friedman and Chi-square tests (α = 0.05). RESULTS: Opaldam and Topdam received the highest scores in most handling features, except for removal, which was similar among all brands. No significant difference was observed in barrier adaptation quality between the evaluated brands. Discomforts were mainly reported in the upper dental arch, with Maxdam having the highest absolute risk (35% for this arch and 24% overall). CONCLUSIONS: This study suggests that gingival barrier brands can influence operator perception and patient comfort. Opaldam and Topdam were preferred by operators, but all brands demonstrated comparable adaptation quality. CLINICAL TRIAL REGISTRATION: The study was nested in a randomized clinical trial registered in the Brazilian Clinical Trials Registry under identification number RBR-9gtr9sc.


Asunto(s)
Sensibilidad de la Dentina , Blanqueadores Dentales , Blanqueamiento de Dientes , Diente , Humanos , Sensibilidad de la Dentina/inducido químicamente , Sensibilidad de la Dentina/prevención & control , Sensibilidad de la Dentina/tratamiento farmacológico , Peróxido de Hidrógeno , Comodidad del Paciente , Percepción , Blanqueamiento de Dientes/efectos adversos , Blanqueadores Dentales/efectos adversos , Resultado del Tratamiento
16.
Eur J Oral Sci ; 132(1): e12958, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37853653

RESUMEN

This clinical trial investigated the effects of pre-application enamel moistening on the impact of a 37% carbamide peroxide whitener on tooth color changes and the influence of repositioning guide colors. Forty participants were randomly assigned to in-office tooth bleaching with either moistened enamel (experimental) or dry enamel (control). The whitener was applied for 45 min over two sessions. Tooth color was visually measured or assessed using a spectrophotometer with purple or green silicone guides. Tooth bleaching was assessed using CIE76 (ΔEab ) and CIEDE2000 (ΔE00 ) formulas and by whitening and bleaching index score changes. Moistening the enamel did not significantly affect tooth color. However, the guide color choice only impacted tooth color when measured instrumentally. At baseline, the green guide resulted in statistically significantly whiter teeth than the purple guide. Less pronounced differences in the b* coordinate between baseline and final measurements were found using the green guide. The green guide also produced lower ΔEab values and less change in indexes. In conclusion, moistening the enamel did not significantly impact tooth color changes. However, the repositioning guide color influenced the tooth bleaching measured instrumentally, except for ΔE00 .


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Decoloración de Dientes , Humanos , Blanqueamiento de Dientes/métodos , Peróxidos/farmacología , Blanqueadores Dentales/farmacología , Urea , Esmalte Dental , Color , Peróxido de Hidrógeno
17.
J Esthet Restor Dent ; 36(2): 402-409, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37681984

RESUMEN

OBJECTIVE: To evaluate the penetration of hydrogen peroxide (HP) into the pulp chamber and the color change of different bleaching varnishes in low concentrations used for at-home bleaching. MATERIALS AND METHODS: Ninety healthy premolars were used, randomly distributed into nine groups (n = 10) according to bleaching varnish (PL, PolaLuminate; VS, VivaStyle Paint On Plus; CA, Cavex Bite&White whitening pen and; AW AlignerWhite) and time (10 and 30 min), and a control group (no bleaching). The penetration of HP was evaluated by UV-Vis spectroscopy. To evaluate the color change (ΔEab , ΔE00 , ΔWID ) a digital spectrophotometer was used (α = 0.05). RESULTS: The AW group in 10 min and the control group showed similar and lower HP penetration in the pulp chamber when compared to the other groups (p = 0.003). Increasing the application time to 30 minutes elevated the amount of HP inside the pulp chamber for all groups (p = 0.003), except for PL (p > 0.05). When applied for 30 min all bleaching varnishes showed higher color change (ΔWID ) when compared to 10 min (p = 0.04). CONCLUSIONS: For all bleaching varnishes evaluated, PolaLuminate applied for 30 min showed lower penetration into the pulp chamber and higher bleaching effects. CLINICAL SIGNIFICANCE: The use of bleaching varnishes seems promising for teeth bleaching, but it varies according to user product and protocol.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Peróxido de Hidrógeno/farmacología , Cavidad Pulpar , Blanqueamiento de Dientes/métodos , Blanqueadores Dentales/farmacología , Espectrofotometría , Color
18.
J Esthet Restor Dent ; 36(3): 460-468, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37728145

RESUMEN

OBJECTIVE: This study aims to assess hydrogen peroxide (HP) penetration into the pulp chamber, color change (CC), physical-chemical properties, and material wastage (MW) and material used (MU) in mixing tips when using in-office bleaching gels with two different mixing tips. MATERIALS AND METHODS: Forty teeth were divided into five groups (n = 8) based on the bleaching gels used (Pola Office +37.5% [PO+] and Whiteness HP Automixx Plus 35% [AM+]) and the mixing tip types (T-Mixer and Helical). A negative control group was treated with ultra-purified water. HP concentration was measured using UV-Vis, and CC was evaluated with a digital spectrophotometer. Initial concentration, pH, and viscosity were measured through Titration, a Digital pH meter, and Rheometer, respectively. MW and MU were measured using a precise analytical balance. Statistical analysis included two-way ANOVA, Tukey's, and Dunnett's test (α = 0.05). RESULTS: A higher HP concentration was observed with PO+ with the Helical mixing tip in comparison with AM+ (p = 0.01). No significant differences in CC or MU were found for different mixing tips (p = 0.001). The T-mixer mixing tip resulted in significantly less MW (p < 0.00001) and improved mixture homogeneity and viscosity. CONCLUSIONS: Utilizing a T-mixer with self-mixing bleaching gels achieves comparable CC while reducing MW. Moreover, it decreases HP penetration when using PO+. CLINICAL SIGNIFICANCE: For the application of a self-mixing in-office bleaching gel, a T-mixer mixing tip should be recommended, as it reduces the penetration of hydrogen peroxide into the pulp chamber when using PO+, while also minimizing gel wastage.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Peróxido de Hidrógeno , Blanqueamiento de Dientes/métodos , Esmalte Dental , Geles , Color
19.
Technol Health Care ; 32(1): 285-292, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37270825

RESUMEN

BACKGROUND: Undesirable effects of tooth bleaching can alter the biomechanical properties of enamel. OBJECTIVE: To determine the influence of strontium fluorophosphate bioactive glass (Sr-FPG) on color, microhardness and surface roughness of enamel bleached with 35% hydrogen peroxide. METHODS: The labial enamel of 36 extracted intact human anterior teeth were divided into 3 groups (n= 12), group 1 (HP): bleaching with 35% hydrogen peroxide only, group 2 (Sr-HP): bleaching with Sr-FPG incorporated 35% hydrogen peroxide and group 3 (HP-SrFPG): bleaching with 35% hydrogen peroxide followed by remineralization with Sr-FPG. Four consecutive eight-minute applications of the bleaching gel were done twice in all the groups. Color change (ΔE), microhardness and surface roughness were evaluated at baseline, post-bleaching and post-remineralization using spectrophotometer, Vickers hardness tester and profilometric analysis respectively. RESULTS: The mean ΔE among the groups was statistically similar (p> 0.05). Bleaching with HP significantly reduced microhardness (p< 0.05), whereas bleaching with Sr-HP and HP-SrFPG did not (p> 0.05). Post-bleaching microhardness in Sr-HP was significantly higher than HP-SrFPG (p< 0.05). An increased surface roughness was seen in Sr-HP bleached samples (p< 0.05). CONCLUSION: The addition of Sr-FPG to hydrogen peroxide significantly improved enamel microhardness than its use post-bleaching. An increase in surface roughness was seen post-bleaching with HP and Sr-HP.


Asunto(s)
Fosfatos , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Peróxido de Hidrógeno/efectos adversos , Blanqueamiento de Dientes/efectos adversos , Fluoruros , Esmalte Dental , Blanqueadores Dentales/farmacología , Color
20.
J Esthet Restor Dent ; 36(3): 429-436, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38130089

RESUMEN

OBJECTIVES: This study aimed to investigate the effect of antioxidant (sodium ascorbate) on tooth sensitivity after two in-office bleaching techniques (light-activated and chemical bleaching). MATERIALS AND METHODS: Ten patients aged 18-25 were bleached in four groups according to bleaching materials and/or antioxidant used. Group A: Maxillary right quadrant received light-activated bleaching with antioxidant. Group B: Maxillary left quadrant received light-activated bleaching without antioxidant. Group C: Mandibular right quadrant received chemical bleaching without antioxidant. Group D: Mandibular left quadrant received chemical bleaching with antioxidant. The tooth sensitivity was recorded using Numerical Rating Scale (NRS) and Schiff Scale (SS) immediately after treatment, 1 day, 1 week, 2 weeks, and 1 month follow-up periods. RESULTS: Group B exhibited higher sensitivity values than Group A. This difference was statistically significant on the first day after treatment (p = 0.027* in NRS and p = 0.046* in SS). Furthermore, antioxidant incorporation in Group D led to a reduction in teeth sensitivity values compared to Group C. This disparity was highly significant on the first day after treatment (p = 0.001* in NRS and p < 0.001** in SS). CONCLUSIONS: The antioxidant (10% sodium ascorbate) reduces the intensity of tooth sensitivity at the different follow-up periods, especially after 1 day from bleaching. CLINICAL SIGNIFICANCE: Using 10% sodium ascorbate after bleaching is advisable to reduce post-operative tooth sensitivity.


Asunto(s)
Sensibilidad de la Dentina , Blanqueadores Dentales , Blanqueamiento de Dientes , Diente , Humanos , Adolescente , Adulto Joven , Adulto , Antioxidantes/farmacología , Blanqueamiento de Dientes/métodos , Ácido Ascórbico , Blanqueadores Dentales/farmacología , Peróxido de Hidrógeno
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...